![Accedian EtherNID GE Скачать руководство пользователя страница 109](http://html1.mh-extra.com/html/accedian/ethernid-ge/ethernid-ge_administrators-manual_3612539109.webp)
7: Operations, Administration and Maintenance
OAM statistics
109
Duplicate event
A count of the OAMPDUs received that contain the Event Notification code. This counter is
incremented on reception of a valid frame, with:
•
DestinationField equal to the reserved multicast address for slow protocols.
•
LengthOrType field value equal to the reserved Type for slow protocols.
•
A slow protocols subtype value equal to the subtype reserved for OAM.
•
The OAMPDU code equals the Event Notification code.
•
The Sequence Number field is equal to the Sequence Number field of the last received
Event Notification OAMPDU.
Generalized nonresettable counter. This counter has a maximum increment rate of slow
protocol frames (No more than 10 frames shall be transmitted in any one-second period).
Loopback control
A count of OAMPDUs received that contain the Loopback Control code. This counter is
incremented on reception of a valid frame, with:
•
DestinationField equal to the reserved multicast address for slow protocols.
•
LengthOrType field value equal to the reserved Type for slow protocols.
•
A slow protocols subtype value equal to the subtype reserved for OAM.
•
The OAMPDU code equals the Loopback Control code and is supported by the device.
Generalized nonresettable counter. This counter has a maximum increment rate of slow
protocol frames (No more than 10 frames shall be transmitted in any one-second period).
Variable request
A count of OAMPDUs received that contain the Variable Request code. This counter is
incremented on reception of a valid frame, with:
•
DestinationField equal to the reserved multicast address for slow protocols.
•
LengthOrType field value equal to the reserved Type for slow protocols.
•
A slow protocols subtype value equal to the subtype reserved for OAM.
•
The OAMPDU code equals the Variable Request code and is supported by the device.
Generalized nonresettable counter. This counter has a maximum increment rate of slow
protocol frames (No more than 10 frames shall be transmitted in any one-second period).
Variable response
A count of OAMPDUs received that contain the Variable Response code. This counter is
incremented on reception of a valid frame, with:
•
DestinationField equal to the reserved multicast address for slow protocols.
•
LengthOrType field value equal to the reserved Type for slow protocols.
•
A slow protocols subtype value equal to the subtype reserved for OAM.
•
The OAMPDU code equals the Variable Response code and is supported by the device.
Generalized nonresettable counter. This counter has a maximum increment rate of slow
protocol frames (No more than 10 frames shall be transmitted in any one-second period).
Содержание EtherNID GE