12
CARE AND MAINTENANCE
LIGHTING
1. Make sure all labels, packing and protective films have been removed from the outdoor fireplace.
2. Check for obstructions of airflow to the burner. Spiders, insects and webs can clog the burner/venturi tube. A clogged
burner tube can lead to a fire.
3. Control knob must be in the “OFF” position.
4. Clear small area of lava rocks away from the pilot housing .
5. Connect LP gas tank per “ Installing gas tank” section.
6. Turn LP gas tank valve to “ON”.
7. Push in gas control knob & turn counter clockwise to “ HIGH”.
8. Manually ignite with match or lighter.
9. After the fire pit lights, release control knob. To decrease the flame, turn the
control knob counterclockwise to "LOW". To increase the flame, turn the
control knob clockwise to "HIGH".
10. After lighting, observe the burner flame. Make sure all burner ports are lit and
flame height matches illustration (Figure 1).
If burner fails to remain lit, all valves should be closed and a waiting period of at least 5 minutes should pass before
attempting to light.
A “poof” sound is normal as the last of the LP gas in burned.
After lighting - using a fireplace tool and heat-resistant gloves, carefully move the lava rocks back to
their proper position, being careful to avoid the flame.
If ignition does not occur in 5 seconds turn burner control knob to “OFF”, wait 5 minutes, fan with a
newspaper or magazine, and repeat lighting procedure.
All cleaning and maintenance should be done when outdoor fireplace is cool and with the fuel supply
disconnected. Do Not clean any outdoor fireplace part in a self-cleaning oven. The extreme heat will
damage the finish. Do Not enlarge valve orifices or burner ports when cleaning the valves or burners.
Cleaning and Care
1. All cleaning and maintenance should be done when outdoor fireplace is cool and with the fuel supply disconnected.
2. Do NOT clean any outdoor fireplace part in self-cleaning oven. The extreme heat will damage the finish.
3. Do NOT enlarge valve orifices or burner ports when cleaning the valves or burners.
Turning Off
1. Turn LP gas tank valve “OFF” .
2. Turn control knob to the “OFF” position.
3. Disconnect LP gas tank per “Disconnecting LP gas tank” section.
15.75 in-19.7 in