11
OPERATING INSTRUCTIONS
CHECKING FOR LEAKS
Before using this outdoor fireplace, make sure you have read, understand and are following all information provided in
the “Warnings” section. Failure to follow those instructions can cause death, serious injury or property damage.
Failure to inspect this connection or follow these instruction which can cause death, serious bodily injury or damage to
property.
Burner connections
1. Make sure the regulator hose and valve connections are securely fastened to the burner and the tank.
2. Visually check the connection between the burner/venturi tube and orifice.
3. Make sure the burner/venturi tube fits over the orifice.
4. Please refer to diagrams for proper installation.
Tank/Gas line connection
1. Make 2-3 oz. of leak detection solution by mixing one part liquid soap with three parts water.
2. Make sure the control knob is in the “OFF” position.
3. Connect LP gas tank per “Installing LP Gas tank” section.
4. Turn LP gas tank valve to “ON”
5. Spoon several drops of solution or use a spray bottle at all connected locations.
a. If any bubbles appear, turn LP gas tank valve “OFF”, reconnect and retest.
b. If you continue to see bubbles after several attempts, turn LP gas tank valve “OFF”
and disconnect LP Gas
tank, per “Disconnecting LP gas tank” section. Contact customer service for assistance.
c. If no bubbles appear after one minute, turn LP gas tank valve “OFF”, wipe away solution and proceed.
Keep outdoor gas appliance area clear and free from combustible material, gasoline and other
flammable vapors and liquid.
Do NOT obstruct the flow of combustion and ventilation air.
Check and clean burner/ venturi tubes for insects and insect nests. A clogged tube can lead to a fire.
Attempting to light the burner with a lid on it may cause an explosion