15 Teaching the wireless components
73
15.6 Menu 6 – Not in use
Option: Switching the display
(supervision monitoring displayed on LEDs: yes/no)
15.7 Menu 7 – External siren behaviour
In this menu, the type of signal from the external siren can be defined.
Press
SELECT
until the seventh LED from the bottom lights up.
Press the
SET
button
once
to go to menu 7.
The central alarm beeps briefly and LED 7 can show the following statuses:
OFF
The external siren does not have a signalling and alarm
function
Note: in this case, CON 3 does not have a function.
ON
permanent External siren function is activated, without any
acknowledgement flash or sound
Flashing
1Hz
External siren function is activated, with acknowledgement
flash and no sound
Flashing
5Hz
External siren function is activated, with acknowledgement
flash and sound
If you want to change the status, press
SET
repeatedly until you reach the required
mode.
To exit programming mode, press
ESC/DEL
until the alarm centre starts to beep
(about once per second). Close the housing or press and hold down the cover
tamper contact (SW4
(B)
, underneath
ESC/DEL
) for about 4 seconds until it beeps
twice. The data is saved in an EEPROM.
15.8 Menu 8 – Setting the default factory settings
Press
SELECT
until the eighth LED from the bottom lights up.
Press
SET
once
to access menu 8.
All blue LEDs start flashing. This signals that the wireless module is ready to reset
itself to the factory settings.
Press and hold down the
ESC/DEL
button for about 4 seconds until the flashing
stops and the alarm centre beeps twice. The factory settings are now restored.
The main menu is accessed again.
To exit programming mode, press
ESC/DEL
until the alarm centre starts to beep
(about once per second). Close the housing or press and hold down the cover
tamper contact (SW4, underneath
ESC/DEL
) for about 4 seconds until it beeps twice.