10 Display and setting elements
14
10.5 Setting elements and connections on the IP board
1. System reset button
2. Restart
button
3. NO
4. NC
5. COM
6. Burglary
7. Fire
8. Panic
9. DSL
monitoring
10. 0 V
11. + terminal for power supply unit
12. – terminal for power supply unit
13. + terminal for battery connection
14. – terminal for battery connection
15. LAN network connection
Restart button (2): this starts the
IP module again and the network
connection. Hold down the button
for about 10 seconds.
Via web server: the system can also be restarted at
“System
Æ
Maintenance
Æ
Restart system”
.
10.6 Restoring the factory settings
To completely restore the alarm centre to the factory settings, you need to reset both
the IP side and the wireless side.
Only reset one of the two sides and keep the settings of the other side. For
example this means, if you only reset the IP side, then you don’t need to
train the wireless components again.
IP board:
•
System reset button (1): this lets you restore the factory settings of the
hardware
on the IP module. This means all the settings you have made with web
server will be lost. To do this, hold down the button for about 10 seconds
(then the LED goes out and the factory settings are restored).
•
Via web server: on the web server, at System
Æ
Maintenance
Æ
Restore
factory settings, you can also reset the settings made on the web server.
Please note that the network settings are also deleted, the alarm centre is
then no longer available through the usual IP address.
Relay outputs
Transistor outputs