
User manual Version 1.5
SW5001 Wireless Serial Server
Copyright © 2010 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan
- 48 -
Running
Serial
to
IP
for
program
on
monitoring
PC
On Window Start Menu,
go to\program\Serial/IP\Control panel\
, The “Serial to IP for Control Panel”
window shall appear. Then select the serial port.
Fig 71. Detail setting from Serial/IP
On the right of the panel is a sample
for COM 4 settings
. On the left is the list of the COM ports that have
been selected (on
Select Ports
window) for use by the
Virtual COM
Redirector. Change the list by clicking
the
Select Ports
button.
Each COM port has its own settings. When click on a COM port, the Control Panel changes to reflect that
the selected port.
Note: COM port changes become effective immediately.
Configure
Virtual
COM
Ports
Serial/IP COM port can be changed as follows:
Select a COM port on the list.
On
IP Address of Server
, enter SW5001 IP address.
On
Port Number
, enter the TCP port number of the SW5001.
On
Server Credentials
, the default is
No Login Required
. If the SW5001 does require login by
the Virtual COM Redirector, the Virtual COM Redirector must provide a username and/or
password every time an application tries to access the SW5001.
Click the
Configuration Wizard
button and then click the
Start
button that shall appear on the
wizard window. This step verifies that the Virtual COM Redirector communicates with the SW5001.
If
Log
display does not show errors, click
Use Settings
, return to the Control Panel
Settings on the
Connection Protocol
must match the TCP/IP protocol supported by the
SW5001. The Configuration Wizard is capable of determining the correct settings.
On
COM Port Options
, the settings must match the COM port behavior expected by the PC
application. The Configuration Wizard will recommend such settings.