User manual Version 1.5
SW5001 Wireless Serial Server
Copyright © 2010 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan
- 26 -
Fig 34. Time service settings from System web page
Select the country from drop-down list box to country that user wants to implement the SW5001. This
selection will be effected to the bands of channel of SW5001 wireless mode. For example, the normal
system level channel configurations for deployments are channels 1, 6 and 11 for FCC countries and 1, 5, 9
and 13 for European Union countries.
5.6.3. Security (change the Password)
Operation: System->Security
Click on the “
Security
” link and the following screen shall appear (
Fig. 35
).
Enter the old password on “
Old Password
” field then enter the new password on “
New Password
” and the
“
Verified Password
” fields, and then click on “
Save Configuration
” to update the password. The maximum
is 8 characters.
Fig 35. Change password from System Security Page
Note: User may press the default reset key to reset password to the default value(blank)
5.6.4. Restoring Factory Default Configurations
Operation: System
Æ
Set to Default
User can click on “
set to default and restart
” button to restore SW5001’s settings to factory default (
Fig.
36
).