User Manual Version 1.5
SE5001 Ethernet Serial Server
Copyright © 2006 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
24
3.3.3 Network Setup
Click on the
“Networking”
link and the following screen appears. Fill in IP information under TCP/IP field.
Alternatively, one can do the configuration by clicking on DHCP to obtain auto IP address, gateway and
subnet mask information.
Enable SNMP by checking “
Enable
”, fill in network identification information under SNMP field and click on
the “Save Configuration” button to save the changes, please notice that the setting will not become effective
until one restart SE5001.( Figure 3.20)
Figure 3.20 Network setup
3.3.4 Configure SE5001 as TCP Server
one can configure SE5001 as transparent mode by default (Figure 3.21)
Click on the
“COM1”
link and the following screen appears.
Configure SE5001 as TCP server
Input local listening port “
4660
”
1.
If one want to enable IP filter
:
Check “
IP filter
”
Input source IP in the “
Source IP
“
2.
If one don’t want to enable IP filter
:
Don’t check “
IP filter
”
Input idle time in “
Please input idle time to send TCP alive packet(sec)
:
”(If one input
2
->the
sending TCP keep alive packet period will be change to 2*10 sec)
Input TCP Inactivity time in “
TCP Inactivity Time Before Disconnect( sec)
:
”(If one input
2
->TCP
Inactivity beyond 2 sec will cause disconnect )