User Manual Version 1.5
SE5001 Ethernet Serial Server
Copyright © 2006 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
21
3.2.9 Setting Packet Delimiter
Packet delimiter is a way of controlling packets within serial communication. It can prevent packets from
being cut thus keep the packets complete. SE5001 provides two ways of parameter setting as inter character
timer and terminator. By default packet delimiter timer is 1 ms, one can change timer shown in the following
figure:( Figure 3.15)
Figure 3.15 Setting packet delimiter timer
One can also choose character pattern as the packet delimiter indicated in the following figure:
(Figure 3.16)
Figure 3.16 Setting packet delimiter-character pattern
3.2.10 Accept Control Command from COM port
SE5001 can also accept serial control commands directly over the network following RFC2217 format. For
more detail about this function, please contact Technical Support for more information.
3.3 Configuration Using Web Browser
1. Make sure ones PC is located on the same network sub-net as SE5001
2. Open a web browser, then type in the IP address of SE5001 to be configured. Default user name is
admin
and default password is
null (leave it blank)
.