User Manual Version 1.5
SE5001 Ethernet Serial Server
Copyright © 2006 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
18
3.2.5 Configure SE5001 as TCP Client
Type
2
in the “
Input choice(1~5) and enter
:
“(Figure 3.11)
Input destination IP in the “
Please input Destination IP
:
”
Input destination port in the “
Please input Destination port
:
”
1.Type
1
for Connected always
:
Double click “
Enter
” key
Input idle time in “
Please input idle time to send TCP alive packet(4*10sec)
:
”(If one input
2
->the
sending TCP keep alive packet period will be change to 2*10 sec)
2.Type
2
for Trigger by receiving COM port data
:
Input idle time to disconnect in the “
Please input idle time to disconnect(0sec , 1~255)
:
” (If one
input
0
->disable the function; if one input
2
->the serial Inactivity beyond 2 sec will cause
disconnect)
Input error retrying time in “
Please input waiting time for error retrying(0 minute,1~255)
:
” (If one
input
0
->disable the function; if one input
2
->the serial Inactivity beyond 2 sec will cause
disconnect)
Double click “
Enter
” key
Input idle time in “
Please input idle time to send TCP alive packet(4*10sec)
:
”(If one input
2
->the
sending TCP keep alive packet period will be change to 2*10 sec)
Figure 3.11 Link Mode-TCP client setup