EN
-
14
4 Commissioning
xFUME
®
PRO/xFUME
®
COMPACT
* When used with welding fume extraction systems of the
xFUME series.
The degree to which welding fumes are captured during torch-
integrated extraction depends on many factors, such as the
position of the suction nozzle, the welding geometry, and the
rate of smoke emission during the welding process. Under
optimal conditions, over 95% of the welding fumes can be
captured in accordance with ISO 21904-3.
3.2 Illustrations used
All illustrations can be found at the beginning of the operating
instructions.
4 Commissioning
► Carry out all steps in the specified sequence.
4.1 Preparing the welding torch for installation of the cable assembly
1
Switch off the power source and unplug the power plug.
2
Switch off the gas and compressed air connector.
4.2 Equipping the torch neck
The MIG/MAG manual welding torches are fully equipped
upon delivery. Information about replacing wear parts and
about the wire guide can be found here:
8 Maintenance and cleaning on page EN
4.3 Connecting the cable assembly, Fig. A
1
At the wire feeder: Insert the central plug in the connecting
socket.
2
At the wire feeder: Secure the cable assembly with the
connection nut.
3
Coolant: Connect the flow line (blue) and return line (red).
► Check the coolant’s minimum fill level.
Recommendation: Use ABICOR BINZEL coolant from the
BTC range.
► To prevent damage to the welding machine, do not use
deionized or demineralized water.
► Purge the coolant circuit the first time the equipment is
commissioned and with every cable assembly replacement.
Tab. 2
Product-specific torch data (EN 60974
-
7 and EN ISO 21904-1)
Type
Type of
cooling
xFUME
®
PRO
xFUME
®
COMPACT
DC Wire
Ø
Gas flow
rate
Volume flow *
Required vacuum
at the connector
For induced velocity 0.35 m/s
Load
Load
Suction
nozzle
Connector
CO
2
M21
CO
2
M21
A
A
A
A
%
mm
L/min
m
3
/h
m
3
/h
kPa
25
Air
-
-
250
230
35 0.8–1.2
10–20
46
85
11.4
24
Air
270
250
-
-
60 0.8–1.2
10–20
70
92.8
11.4
36
Air
330
300
-
-
60 0.8–1.2
10–20
58.7
75.8
5.8
501
Liquid
500
450
-
-
100 1.0–1.6
10–20
58.7
81.3
6.6
Tab. 3
Cooling data/cable assembly
Cooling data
Cable assembly
Supply temp.
Max. 40 °C
Standard length L
4.00 m, 5.00 m
Flow
Min. 1.5 L/min
Coolant connection
Plug-in nipple with nom. diam. 5
Flow pressure
Min. 2.5 bar/max. 3.5 bar
Cooling device output
Min. 800 W
Control lead
2-lead
WARNING
Health risk caused by inhaling harmful dust
The device contains harmful dust that can collect on surfaces and penetrate the ambient air as of the first use. It can damage the
respiratory tract when inhaled.
► Check and wear your personal protective equipment.
► Use the device only in rooms with sufficient ventilation.
► The provided fume extraction system must be used when operating the device.
► Immediately remove dust deposits from the environment with a dust class H industrial vacuum cleaner or a damp cloth.
► Keep the air regulator closed if possible, and then open it only briefly.