xFUME
®
PRO/xFUME
®
COMPACT
3 Product description
EN
-
13
► Observe the warning signals and indicators on the fume
extraction system. Warning signals and indicators can imply
a saturated filter or a problem with/damage to the fume
extraction torch.
► Replace the extraction-specific wear parts at regular
intervals. The replacement interval required depends on the
application conditions.
► Open the air regulator for only a moment and close it
quickly after opening it. The air regulator must be closed to
ensure efficient capture of fumes.
► Observe the instructions on the adapter label for connecting
components.
2.6 Safety instructions for personal protective equipment
► Do not wear loose fitting clothing or jewelry.
► Use a hair net for long hair.
► Wear safety goggles, protective gloves and, if required,
a breathing mask when the device is in use and when
welding.
2.7 Safety instructions for use
► Do not exceed the maximum load data as defined by the
documentation supplied. Excessive loads lead to irreparable
damage.
► Do not make any constructive changes to this device.
► During welding work outdoors, use suitable protection
against the weather conditions.
2.8 Classification of the warnings
The warnings used in the operating instructions are divided into
four different levels and shown prior to potentially dangerous
work steps. Arranged in descending order of importance, they
have the following meanings:
2.9 Emergency information
► In the event of an emergency, immediately disconnect the
following supplies: electrical power supply, compressed air
supply, coolant supply and shielding gas supply.
► Consult the documentation for welding components.
3 Product description
3.1 Technical data
DANGER
Describes an imminent threatening danger. If not avoided, it may cause severe injuries or death.
WARNING
Describes a potentially dangerous situation. If not avoided, this may result in death or serious injuries.
CAUTION
Describes a potentially harmful situation. If not avoided, this may result in slight or minor injuries.
NOTICE
Describes the risk of impairing work results or material damage and indicates irreparable damage to the device or equipment.
Tab. 1
General torch data (EN 60974-7)
Temperature
(transport and storage)
−25 °C to +55 °C
Shielding gas
(DIN EN ISO 14175)
CO
2
and mixed gases M21
Temperature (operation)
−10 °C to +40 °C
Wire types
Commercially available
round wires
Relative humidity
Up to 90% at 20 °C
Voltage rating
Peak value of 113 V
Type of use
Hand-held
Protection type of the device
connections (EN 60529)
IP3X
Type of voltage
DC
Control features in the handle
For 42 V and 0.1 to 1 A
Polarity of the electrodes for DC
Usually positive