11 Disassembly
xFUME
®
POWER 250
11 Disassembly
Perform the following steps in reverse order:
Fig. 2 Control elements on page EN
1
Unplug the mains plug
Fig. 5 Connecting the cable assembly on page EN
2
Disassemble the welding torch cable assembly
and connection for
.
Porous welding seam.
Unclean workpiece surface (paint,
rust, oil, grease).
► Clean the surface.
No shielding gas (solenoid valve
does not open).
► Check the solenoid valve and
replace it if necessary.
See service manual.
► Check the gas cylinder and
connection, and replace if
necessary.
► Observe the information provided
by the manufacturer.
Insufficient shielding gas.
► Check the shielding gas volume at
the pressure reducer and adjust if
necessary.
Observe the information
provided by the manufacturer.
► Check the gas flow for loss of gas
with a gas metering tube and
replace if necessary.
► Observe the information provided
by the manufacturer.
No extraction capacity.
Filter is full.
► Replace the filter.
Differential pressure
switch activates/LED
illuminates.
Tab. 9
Faults and troubleshooting
Fault
Cause
Troubleshooting
CAUTION
Risk of injury due to unexpected start
If power is supplied during maintenance, cleaning or disassembly, rotating parts can start running
unexpectedly and lead to injuries from cuts.
► Switch off the device.
► Disconnect all electrical connections.