![Abicor Binzel xFUME POWER 250 Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/abicor-binzel/xfume-power-250/xfume-power-250_original-operating-instructions_451547065.webp)
xFUME POWER 250
9 Maintenance and cleaning
EN
-
29
9.6 Replacing the drive roll
4
Remove the locking ring.
5
Remove the pins.
6
Remove the pressure roll, replace it and mount it
again in reverse order.
NOTICE
► Observe the groove geometry and the wire diameter. The wire electrode and drive rolls must be
compatible with each other.
► All grooved drive rolls have two guide grooves: 0.8 mm and 1.0 mm. If worn, the drive rolls cannot
be used and must be replaced.
► Always replace/change the drive rolls in pairs.
► The drive rolls should be changed whenever the wire type or the wire diameter are changed or the
drive rolls are worn out.
1
Open the cover.
2
Open the clamp lever outward.
Содержание xFUME POWER 250
Страница 37: ...xFUME POWER 250 13 Gewährleistung DE 37 ...