Fault
Cause
Solution
The system cannot be
switched on (green
LED off)
• No mains voltage on supply socket
• Check the electric system and repair it if necessary
• Plug or supply cable defective
• Replace the defective part
• Have it repaired by the customer service
• Mains fuse blown
• Replace the defective part
• Main switch defective
• Replace the defective part
• Have it repaired by the customer service
No output power (no
welding takes place)
• No start signal
• Check robot output for start
• Check robot interface
• Replace the defective part
• Have it repaired by the customer service
• System overheated
(Overtemperature alarm - yellow LED on)
• Wait for the system to cool down, do not switch off
the system!
• Allowed duty cycle exceeded
No output power (no
welding takes place)
• Connection to ground not carried out correctly
• Make sure that the connection to ground is correct
6 Putting into operation on page EN-13
• Mains voltage outside the range of the allowed
operating voltage (yellow LED on)
• Bring mains voltage again inside the range of the
allowed operating voltage of the power source
• Establish proper connection
• Electronic system defective
• Have it repaired by the customer service
Wrong output power • Wrong selection of the welding process
• Select the correct welding process
• Wrong parameter setting and functions of the
system
• Set the welding parameters correctly
• Potentiometer / encoder for regulating the
welding current defective
• Replace the defective part
• Have it repaired by the customer service
Tab. 11
Troubleshooting
Содержание iRob P400
Страница 25: ...iROB 13 Anhang DE 25 13 2 Schaltplan iROB P400 Abb 10 iROB P400 ...
Страница 26: ...DE 26 13 Anhang iROB 13 3 Schaltplan iROB P400 MV Abb 11 iROB P400 MV ...
Страница 27: ...iROB 13 Anhang DE 27 13 4 Schaltplan iROB P500 Abb 12 iROB P500 ...
Страница 54: ...EN 26 13 Appendix iROB 13 2 Circuit diagram iROB P400 Fig 10 iROB P400 ...
Страница 55: ...iROB 13 Appendix EN 27 13 3 Circuit diagram iROB P400 MV Fig 11 iROB P400 MV ...
Страница 56: ...EN 28 13 Appendix iROB 13 4 Circuit diagram iROB P500 Fig 12 iROB P500 ...
Страница 59: ...iROB 14 Options EN 31 ...
Страница 83: ...iROB 13 Annexe FR 25 13 2 Schéma électrique iROB P400 Fig 10 iROB P400 ...
Страница 84: ...FR 26 13 Annexe iROB 13 3 Schéma électrique iROB P400 MV Fig 11 iROB P400 MV ...
Страница 85: ...iROB 13 Annexe FR 27 13 4 Schéma électrique iROB P500 Fig 12 iROB P500 ...
Страница 111: ...iROB 13 Anexo ES 25 13 2 Diagrama de circuito iROB P400 Fig 10 iROB P400 ...
Страница 112: ...ES 26 13 Anexo iROB 13 3 Diagrama de circuito iROB P400 MV Fig 11 iROB P400 MV ...
Страница 113: ...iROB 13 Anexo ES 27 13 4 Diagrama de circuito iROB P500 Fig 12 iROB P500 ...
Страница 139: ...iROB 13 Allegato IT 25 13 2 Schema elettrico iROB P400 Fig 10 iROB P400 ...
Страница 140: ...IT 26 13 Allegato iROB 13 3 Schema elettrico iROB P400 MV Fig 11 iROB P400 MV ...
Страница 141: ...iROB 13 Allegato IT 27 13 4 Schema elettrico iROB P500 Fig 12 iROB P500 ...