iROB
®
501, iROB
®
401, iROB
®
301
13 IFR-800 fieldbus connection tool
EN
-
69
6
–
Arc characteristic
Specifies the arc characteristic.
7.4.1 Setting the arc characteristic on page EN
7
–
En ratio
Specifies the En ratio. The unit for this setting is [%].
The En ratio is the ratio between the negative and positive
polarized part of the electrode during AC welding.
Available only with iROB
®
401.
8
0
Voltage setting for
synergetic mode
When set to 1, the synergetic mode is used for the voltage
setting.
Setting the welding voltage on page EN
In addition, the voltage settings of offsets 13 and 14 are
deactivated and offset 15 is activated for fine adjustment of
the welding voltage in synergetic mode.
8
1
Setting for wire feed
speed
When set to 0, offsets 9 and 10 are activated for the
welding current. When set to 1, offsets 11 and 12 are
activated for the wire feed speed.
F24: Setting the wire feed speed on page EN
8
2
Setting for wire feed-
in rate
The setting for this bit is only enabled when the setting for
the wire feed-in rate for offset 8/bit 1 is 0 (welding current
setting). When this is bit 1, wire feed-in with the setting for
the wire feed-in rate for offset 11 and 12 is performed only
in wire feed and wire retract modes. When this is bit 0, the
wire feed-in rate is set in relation to the welding current
setting.
If the setting for the wire feed-in rate for offset 8/bit 1 is 1
(setting for wire feed-in rate), wire feed and wire retract are
performed with the settings for the wire feed-in rate for
offsets 11 and 12.
Tab. 36 Settings for wire feed-in rate on page EN
9–10
–
Welding current
Specifies the welding current. The unit for this setting is [A].
For information on how to apply this setting value, refer to
the description of the setting for the wire feed speed
for offset 8/bit 1 and the setting for the wire feed speed for
offset 8/bit 2.
11–12
–
Wire feed speed
Specifies the wire feed speed. The unit of this setting
is [0.1 m/min] or [inch/min]. (according to the device
display). For information on how to apply this setting value,
refer to the description of the setting for the wire feed speed
for offset 8/bit 1 and the setting for the wire feed speed
for offset 8/bit 2.
13–14
–
Welding voltage
Specifies the welding voltage. The unit for this setting
is [0.1 V]. For information on how to apply this setting value,
refer to the description of the setting for voltage synergy
(offset 8/bit 0).
15
–
Fine adjustment of
welding voltage for
synergetic mode
Specifies the synergetic mode for the welding voltage.
Setting the welding voltage on page EN
For information on how to apply this setting value,
refer to the description of the setting for voltage synergy
(offset 8/bit 0).
16–17
–
Move frequency
(not available for
iROB
®
301)
Specifies the move frequency.
7.4.3 Adjusting the move frequency on page EN
The unit for this setting is [0.1 Hz].
Tab. 29
Details of output data
Byte
Bit
Function
Description