EN - 18
10 Troubleshooting
MT/AUT/AUT RAB
9.1 Hose assembly
See Fig. 3 Mounting the guide spiral liners on page EN-11
1
Unscrew the hose assembly
on the machine side and bring it into a
stretched position.
2
Unscrew union nut
and pull out guide spiral liner or PA liner and replace
it, if necessary.
3
.
4
Clean wire feed hose
from both sides with compressed air.
5
Slide adjusted guide spiral liner or PA liner into wire feed hose
secure with union nut
.
6
Connect hose assembly on the machine side with wire feed unit
.
9.2 Torch neck
1
Remove gas nozzle.
2
Remove welding spatter and spray gas nozzle with the
ABICOR BINZEL
antispatter agent.
3
Check wearing parts for visible damage and replace them, if required.
10 Troubleshooting
WARNING
Risk of injury
Serious injuries caused by parts swirling around.
• When cleaning the wire guide with compressed air, wear suitable
protective clothing, in particular safety goggles.
NOTE
• Some problems are listed below, with descriptions of possible causes
and solutions. If the measures described below are not successful, please
consult your dealer or the manufacturer.
• Please also consult the operating instructions for the welding
components, such as the power supply, welding torch system, re-
circulating cooling unit, etc.