EN - 11
MAG welding torches
6 Putting into operation
1
Disconnect the coolant return hose
from the re-circulating cooling
unit
and hold it over a collecting device.
2
Close the opening at the coolant return hose
and open it again by
repeatedly and abruptly releasing it, until the coolant is flowing
continuously and without air bubbles into the collecting device.
3
Switch off the re-circulating cooling unit
and reconnect the coolant
return hose
NOTE
• Do not use any deionized or demineralized water as coolant or for
tightness or flow tests.
This may impair the service life of your welding torch.
• We recommend the use of
ABICOR BINZEL
series BTC coolant for
liquid-cooled welding torches.
• Each time the device is commissioned or after each cable assembly
change, the cooling system must be ventilated as follows:
1
Coolant return hose
2
Coolant flow hose
3
Re-circulating cooling unit
Fig. 4
Connecting the coolant
1
2
3
NOTE
• Repeat this procedure until the coolant is drained continuously and
without air bubbles.
• Check the minimum coolant level of the cooling device.