EN - 12
6 Operation
TIG cold wire feeder
5.8 Changing the driving rollers
If required, the wire must be cut through and then fed in again.
5.7 Feeding in the wire on page EN-11
1
Open cover at the
ABIDRIVE CW
.
2
Fold pressure lever
forward.
3
Swing the the pressure rocker
open using the pressure rolls
.
4
Unscrew locking screws
5
Replacing the driving rollers
.
6
Screw in locking screws
and close pressure rocker
7
Fold pressure lever
upward.
Re-adjust the required contact pressure via the pressure lever
8
Close the cover.
This completes changing the driving rollers
6 Operation
1
Pressure lever
2
2 pressure rolls
3
2 driving rollers
4
2 full-floating axles
5
2 locking screws
6
Pressure rocker
Fig. 7
Changing the driving rollers
NOTICE
• The driving rollers should be changed whenever the wire type or the wire diameter are changed or
the driving rollers are worn out.
• Change or reverse the driving rollers always in pairs
• Observe the groove geometry and the wire diameter.
1
2
3
4
5
6
NOTICE
• As the
ABIDRIVE CW
is integrated into a welding system, the operating instructions of the welding
components, such as welding torch and welding power source, must be observed during operation. In
addition, the safety instructions for the welding process must be observed.
• The
ABIDRIVE CW
may only be operated by qualified personnel.