EN - 8
5 Putting into operation
TIG cold wire feeder
4.1 Transport
The scope of delivery is carefully checked and packaged, however damage may occur during shipping.
4.2 Storage
Physical storage conditions in a closed environment:
Tab. 1 Ambient conditions on page EN-4
5 Putting into operation
5.1 Installation
Checking procedure
on receipt of goods
Make sure that the shipment is complete by referring to the delivery note!
Check the delivery for damage (visual inspection)!
In case of complaints
If the delivery has been damaged during transport, contact the last carrier
immediately! Keep the packaging for possible checks by the carrier.
Packaging for return
shipment
Use the original packaging and the original packaging material. If you have
questions concerning the packaging and safety during shipment, please
consult your supplier, carrier or transporter.
Tab. 6
Transport
NOTICE
• The
ABIDRIVE CW
must be transported and operated in upright position only.
DANGER
Risk of injury due to unexpected start-up
An unexpected start-up of the device can result in very serious injuries.
• Prior to performing work on the system, de-energise the entire system.
• Close off the compressed air supply.
• Close off the gas supply.
NOTICE
• The system may only be put into operation by authorised personnel (in Germany see TRBS 1203).
WARNING
Risk of injury due to tilting of ABIDRIVE CW
Risk of crushing of body parts due to
• When installing the
ABIDRIVE CW
the tilting stability is guaranteed up to an angle of 15°. Do not
exceed the angle of 15°.
• Install the
ABIDRIVE CW
ensuring a stable position and secure it.