ABEM Terraloc Pro 2
74
FIR Filter
The
FIR
filters (Finite Impulse Response) are used to reduce noise from the recorded
data.
Note!
The abbreviation FIR in this filter context is not the
same as FIR used in the first breaks context
The
FIR filter
dialog (Figure 62) is accessed from the data
Context Menu
Figure 62 The FIR filter dialog
Clicking OK will apply the filter to the current data.
Setting
Description
Filter type -
Selects the type of filter to apply to data. The following types are
available:
Name
Description
Low pass
Rejects frequencies higher than the high cut-off
High pass
Rejects frequencies lower than the low cutoff
Band pass
Rejects frequencies lower than the low cut-off and higher
than the high cut-off
Band reject Rejects frequencies between the low cut-off and high
cut-off
Windowin
g function
-
Data windowing function to apply to the data when filtering.
Available values are: Hanning and Blackman
Cut-off
frequencies
-
The cut-off frequencies are specified as the frequency where the pass
band signal has been reduced by 3 dB and the transition band starts.
The low- and high pass filters only specifies a single cut-off
frequency, while the band pass and band reject filters specifies two
frequencies, low- and high cut-off
Filter
length
-
The number of filter coefficients used to realize the filter. The longer
the filter, the steeper its slope, i.e. it will cut the signal more abruptly.
A longer filter also takes longer to apply, especially to long records
Содержание Terraloc Pro 2
Страница 1: ...User Manual Terraloc Pro 2 ABEM 20181009 based on release 3 0 4 of SeisTW ...
Страница 6: ...ABEM Terraloc Pro 2 iv ...
Страница 73: ...ABEM Terraloc Pro 2 71 Free end to the left Free end to the right Free end up Free end down Free end left ...
Страница 74: ...ABEM Terraloc Pro 2 72 Free end up Moved to the right ...