2104349 rev. AD
Page 4
–7
To extend the lift of the battery pack, fully charge the battery
prior to installation. A system using solar panels may not fully
charge the battery. Additionally, a fast charge, which the
solar panel cannot provide, improves the life of the battery.
To recharge a battery, a quick charge will remove buildup in
the battery much more effectively than a trickle charge. A
battery slowly drained by low light conditions on a solar
charged system or setting in storage will be less likely to
recover than a battery pack that was quickly discharged from
a short. Store batteries in a cool environment for less
drainage.
Figure 4
–3 6270 OEU Configuration
4.7.1 Step-by-step instructions
1) Collect the data from the unit.
2) Back up the configuration files following the instructions listed previously in
this chapter.
3)
Verify the “LL” alarm battery alarm is not being displayed on the G4 EX’s
display. This prevents any data stored in RAM from being lost when power
is removed.
4) Disconnect the charging source from the charger regulator.