SACE Tmax XT2
– XT4 | 180
Menu
The activation of the local bus
– essential to start the communication between the module and
the Trip unit
– is available in the
Settings
menu (page 29).
If the
Ekip CI
module is correctly detected by Ekip Touch, the corresponding configuration,
measurement, test, and information areas are activated in the respective menus.
Configuration
In the
Settings-Modules-Ekip CI
menu it is possible to configure the parameters of the module:
Parameter
Description
Default
Enable
Enable/disable some functions and the availability of the
parameters in the menu
If On: all the inputs and outputs are active, as are their functions
If Off: only input I61 is active. The O61 control function is off
Off
Polarity
Defines if input I63 is interpreted as On by Ekip Touch when it is
open (Active open) or when it is closed (Active closed)
Active
closed
Delay
Minimum duration of activation of input I63 before sending the
reopening command for contact O61. The delay is expressed in
seconds, which can be set in a range: 0 s .. 100 s with 0.01 s steps
NOTES:
If the input is deactivated before this time has
elapsed, the re-opening command is not sent
With delay = 0 s, the input must still be present for
more than 300
S
0.1 s
Measurements
If
Ekip CI
is correctly detected by Ekip Touch, the specific area for the module is made available
in the
Measurements
menu, where the temperature measurement of the PT100 probe is
displayed if connected and active.
NOTE: if no probe is detected the value "- - -" is displayed
Test
If the
Ekip CI
module is correctly detected, the test area is activated in the
Test
menu.
For more on the test see page 30.
Information
If
Ekip CI
is correctly detected by Ekip Touch, the specific area for the module is made available
in the
Information-Modules
menu, displaying:
The module's serial number and version
The activation state for the PT100 temperature probe input
Remote
information
Some additional information regarding the version and status of the module are available from
the service connector (via Ekip Connect) or the system bus communication: HW and Boot
version, CRC status (correctness of the SW on the module).
Содержание SACE Tmax XT2
Страница 82: ...1SDH002031A1002 ECN000092998 Rev B SACE Tmax XT2 XT4 82 L curve IEC 60255 151 SI L curve IEC 60255 151 VI ...
Страница 83: ...1SDH002031A1002 ECN000092998 Rev B SACE Tmax XT2 XT4 83 L curve IEC 60255 151 EI L curve t k I4 ...
Страница 84: ...1SDH002031A1002 ECN000092998 Rev B SACE Tmax XT2 XT4 84 L curve Ekip M Touch S curve t k I2 ...
Страница 85: ...1SDH002031A1002 ECN000092998 Rev B SACE Tmax XT2 XT4 85 S curve t k Curve S2 I curve MCR curve 2I curve ...
Страница 86: ...1SDH002031A1002 ECN000092998 Rev B SACE Tmax XT2 XT4 86 G curve t k I2 G curve t k ...
Страница 87: ...1SDH002031A1002 ECN000092998 Rev B SACE Tmax XT2 XT4 87 IU curve UV curve UV2 curve ...
Страница 88: ...1SDH002031A1002 ECN000092998 Rev B SACE Tmax XT2 XT4 88 OV curve OV2 curve VU curve ...
Страница 89: ...1SDH002031A1002 ECN000092998 Rev B SACE Tmax XT2 XT4 89 S V curve S2 V curve RV curve ...
Страница 90: ...1SDH002031A1002 ECN000092998 Rev B SACE Tmax XT2 XT4 90 UF curve UF2 curve OF curve OF2 curve ...
Страница 91: ...1SDH002031A1002 ECN000092998 Rev B SACE Tmax XT2 XT4 91 RP curve D curve ...
Страница 92: ...1SDH002031A1002 ECN000092998 Rev B SACE Tmax XT2 XT4 92 OQ curve OP curve ...
Страница 93: ...1SDH002031A1002 ECN000092998 Rev B SACE Tmax XT2 XT4 93 UP curve RQ curve ...
Страница 94: ...1SDH002031A1002 ECN000092998 Rev B SACE Tmax XT2 XT4 94 ROCOF curve R JAM curve R STALL ...
Страница 95: ...1SDH002031A1002 ECN000092998 Rev B SACE Tmax XT2 XT4 95 UC curve ...
Страница 207: ...1SDH002031A1002 ECN000092998 Rev B ...