Communication
92
I&M0 Device identification (read-only)
I&M1 Task identification
I&M2 Installation date
Content
Size
Description
Header
10 bytes
-
Vendor ID
2 bytes
PROFINET Vendor ID of ABB, which is 26
(0x001A)
Order ID
20 bytes
Order number of the RETA-02 adapter kit
Serial number
16 bytes
Serial number of the adapter
Hardware revision
2 bytes
Hardware revision of the RETA-02 adapter
Software revision
4 bytes
Revision of the software
Revision counter
2 bytes
Number of revision
Profile ID
2 bytes
PROFIdrive (0x3A00)
Profile specific type
2 types
No profile specific type (0x0000)
I&M version
2 types
Version is 1.1 (0x0101)
Supported I&M
functions
2 types
I&M0-I&M4 are supported (0x0017)
Content
Size
Description
Header
10 bytes
-
TAG_FUNCTION
32 bytes
The function or task of the drive can be
described here
TAG_LOCATION
22 bytes
The location of the drive can be described here
Content
Size
Description
Header
10 bytes
-
INSTALLATION_DATE
16 bytes
This parameter indicates the date and time
of installation. Date and time according to
ISO 8601. Example: 2007-02-28 13:30
(YYYY-MM-DD hh:mm)
Содержание RETA-02
Страница 1: ...ABB Drives User s Manual Ethernet Adapter Module RETA 02 ...
Страница 2: ......
Страница 4: ......
Страница 6: ...Safety instructions 6 ...
Страница 10: ...Table of contents 10 ...
Страница 14: ...Introduction 14 ...
Страница 30: ...Mechanical installation 30 ...
Страница 32: ...Electrical installation 32 ...
Страница 42: ...Drive configuration 42 ...
Страница 48: ...Network configuration 48 ...
Страница 50: ...Master configuration 50 ...
Страница 58: ...Communication profiles 58 11 to 15 Drive specific Bit Name Value STATE Description ...
Страница 68: ...Communication profiles 68 ...
Страница 106: ...Diagnostics 106 ...
Страница 111: ......