Network configuration
46
Settings stored
in RETA-02
configuration
parameters
Use the configuration stored in the RETA-02
configuration parameters. See
Table 4.
in
chapter
Drive configuration
.
RETA-02 must
be started for
any
configuration
changes to take
effect.
Gleaning
(ARP)
Change the IP address from a PC using the
following commands:
arp -s <IP address> <MAC address>
ping <IP address>
arp -d <IP address>
The
arp -s
command will store the IP and
MAC addresses in the PC ARP table. When
the
ping
command is executed, the PC will
send the message to the module using the
MAC address. The module changes its IP
address to the given one.
The MAC
address of the
module can be
found on a label
on the RETA-02
module.
DCP
(Discovery and
Configuration
Protocol)
The DCP protocol is used for setting the IP
address and for assigning a station name of
a PROFINET IO node.
Usually included
to a
configuration
tool, like Step7.
This protocol
cannot be used
with
Modbus/TCP.
Method
Description
Note
Содержание RETA-02
Страница 1: ...ABB Drives User s Manual Ethernet Adapter Module RETA 02 ...
Страница 2: ......
Страница 4: ......
Страница 6: ...Safety instructions 6 ...
Страница 10: ...Table of contents 10 ...
Страница 14: ...Introduction 14 ...
Страница 30: ...Mechanical installation 30 ...
Страница 32: ...Electrical installation 32 ...
Страница 42: ...Drive configuration 42 ...
Страница 48: ...Network configuration 48 ...
Страница 50: ...Master configuration 50 ...
Страница 58: ...Communication profiles 58 11 to 15 Drive specific Bit Name Value STATE Description ...
Страница 68: ...Communication profiles 68 ...
Страница 106: ...Diagnostics 106 ...
Страница 111: ......