34
Table 4. The RETA-02 configuration parameters
Par.
no.
Parameter name Alternative settings
Default
setting
1
MODULE TYPE
(Read-only)
PROFINET IO
2
Comm rate
(0)
Auto-negotiate;
(1)
100 Mbit/s,
full duplex;
(2)
100 Mbit/s, half
duplex;
(3)
10 Mbit/s, full duplex;
(4)
10 Mbit/s, half duplex
(0)
Auto-negotiate
3
DHCP
(0)
DHCP disabled;
(1)
DHCP
enabled
(1)
DHCP enabled
4
IP address 1
0…255
0
5
IP address 2
0…255
0
6
IP address 3
0…255
0
7
IP address 4
0…255
0
8
Subnet mask 1
0…255
0
9
Subnet mask 2
0…255
0
10
Subnet mask 3
0…255
0
11
Subnet mask 4
0…255
0
12
GW address 1
0…255
0
13
GW address 2
0…255
0
14
GW address 3
0…255
0
15
GW address 4
0…255 (0)
0
16
Protocol
(0)
Modbus/TCP;
(1)
PROFINET IO
(0)
Modbus/TCP
17
Modbus timeout
0…65535
0
18
Output 1
0…65535
0
19
Output 2
0…65535
0
20
Output 3
0…65535
0
21
Output 4
0…65535
0
22
Input 1
0…65535
0
Содержание RETA-02
Страница 1: ...ABB Drives User s Manual Ethernet Adapter Module RETA 02 ...
Страница 2: ......
Страница 4: ......
Страница 6: ...Safety instructions 6 ...
Страница 10: ...Table of contents 10 ...
Страница 14: ...Introduction 14 ...
Страница 30: ...Mechanical installation 30 ...
Страница 32: ...Electrical installation 32 ...
Страница 42: ...Drive configuration 42 ...
Страница 48: ...Network configuration 48 ...
Страница 50: ...Master configuration 50 ...
Страница 58: ...Communication profiles 58 11 to 15 Drive specific Bit Name Value STATE Description ...
Страница 68: ...Communication profiles 68 ...
Страница 106: ...Diagnostics 106 ...
Страница 111: ......