![ABB REACT 2 Series Скачать руководство пользователя страница 69](http://html.mh-extra.com/html/abb/react-2-series/react-2-series_product-manual_4161069.webp)
- 69 -
000898AG
5 - Installation
In the picture below are described the components of the counterpart
connector and the relative torques:
25mm
5mm
RS485 METER
cable
Clamping ring
Pressing screw
Gasket
Housing
Male head
Torque 1Nm
Cable diameter
4 - 6 mm
M2.5 screw
Torque 0.2Nm
0.75mm max.
Mating Torque
0.6Nm
Torque 0.6Nm
2
Follow the procedure to connect the RS485 cable to the counterpart
(supplied) of the METER connector
14
:
1. Disassembly the counterpart connector
2. Install all components on the RS485 cable
3. Strip the cable as indicated in the picture
4. Install the wire on the head of the connector following the indication below:
Screw terminal on the
counterpart connector
RS485 METER signal
1
-T/R
3
+T/R
4
RTN
Turn the M2.5 screw with suitable screwdriver (torque 0.2Nm)
5. Install connector housing (torque 0.6Nm)
6. Install seal, pinch ring, pressing screw
7. Pressing screw should be tightened with torque 1Nm
8. Install the counterpart on the METER connector
14
by screwing the
metallic ferrule (torque 0.6Nm).
*LYHHDFKFDEOHDSXOOWHVWWRFRQ¿UPWKHFRQQHFWLRQLVVHFXUH
The cable of the cable assembly must remain perpendicular to the connector and avoid an
excessively sharp bend radius and loading. The minimum bend radius of a cable is ±10°.
Содержание REACT 2 Series
Страница 1: ...ABB solar inverters Product manual REACT 2 3 6 to 5 0 kW ...
Страница 159: ...Contact us www abb com solarinverters ...