Solution
E068
- Charger - OC
-
(On)
Overcurrent of "battery charger" ("Charger"
circuit):
Error inside the charger (battery unit).
(UURULQVLGHWKHFKDUJHUEDWWHU\XQLWDQGFDQQRWEHFKHFNHG
externally.
- If the problem persists, contact customer assistance.
E069
- Charger-SlowRamp
-
(On)
Error internal to battery unit charger circuit
("Charger" circuit").
(UURULQVLGHWKHFKDUJHUEDWWHU\XQLWDQGFDQQRWEHFKHFNHG
externally.
- If the problem persists, contact customer assistance.
E070
- Charger-preChar.
-
(On)
Error inside the charger (battery unit).
(UURULQVLGHWKHFKDUJHUEDWWHU\XQLWDQGFDQQRWEHFKHFNHG
externally.
- If the problem persists, contact customer assistance.
E077
- Internal Error
-
(On)
(UURULQWKHV\VWHPFRQ¿JXUDWLRQ
Error inside the inverter
(UURULQVLGHWKHLQYHUWHUDQGFDQQRWEHFKHFNHGH[WHUQDOO\
- If the problem persists (once the inverter has been switched
off and back on again), contact customer assistance.
E078
- Riso Test fail
-
(On)
Riso test error:
Problem detected during the Riso test phase.
(UURULQVLGHWKHLQYHUWHUDQGFDQQRWEHFKHFNHGH[WHUQDOO\
- If the problem persists (once the inverter has been switched
off and back on again), contact customer assistance.
E084
- BackFeed OC
-
(On)
5HWXUQFXUUHQWWRSKRWRYROWDLF¿HOG
The error occurs if the input voltage is particularly low
(typically in the evening in conditions of low irradiation)
and indicates a return current from the inverter to the
photovoltaic panels).
If the error occurs in the evening or in conditions of low
irradiation, it must not be considered a problem but a
SURWHFWLRQLQWHUYHQWLRQIRUWKHSKRWRYROWDLF¿HOG
- If the error occurs with good irradiation conditions, switch
the inverter off and back on again; if the error persists, contact
customer assistance.
E086
- Batt. 1 - F2
-
No Icon
Error battery unit 1 unusable:
Indicates that the battery unit is unusable and must be
replaced.
(UURULQVLGHEDWWHU\XQLWDQGFDQQRWEHFKHFNHGH[WHUQDOO\
If the problem (once the system has been switched off and
back on) persists, contact customer assistance.
E087
- Batt. 2 - F2
-
No Icon
Error battery unit 2 unusable:
Indicates that the battery unit is unusable and must be
replaced.
(UURULQVLGHEDWWHU\XQLWDQGFDQQRWEHFKHFNHGH[WHUQDOO\
If the problem (once the system has been switched off and
back on) persists, contact customer assistance.
E088
- Batt. 3 - F2
-
No Icon
Error battery unit 3 unusable:
Indicates that the battery unit is unusable and must be
replaced.
(UURULQVLGHEDWWHU\XQLWDQGFDQQRWEHFKHFNHGH[WHUQDOO\
If the problem (once the system has been switched off and
back on) persists, contact customer assistance.
E089
- Wrong Wiring
-
(On)
Incorrect grid wiring connection on Backup output:
The error occurs if the grid cables have been
incorrectly connected to the Backup output.
&KHFNWKDWWKHFDEOHVRQWKH%DFNXSRXWSXWKDYHEHHQ
installed correctly.
E096
- CHARGER - battery UV
-
(On)
Battery under voltage:
The voltage of the battery is too low and need to be
charged. In this condition the discharge of the battery
is disabled.
7KHEDWWHU\ZLOOEHDXWRPDWLFDOO\FKDUJHGDVVRRQDVWKH
condition will allow it.
E097
- CHARGER - battery HW
-
(On)
Error inside the battery unit.
(UURULQVLGHEDWWHU\XQLWDQGFDQQRWEHFKHFNHGH[WHUQDOO\
If the problem (once the system has been switched off and
back on) persists, contact customer assistance.