![ABB REACT 2 Series Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/abb/react-2-series/react-2-series_product-manual_4161020.webp)
- 20 -
000887AG
2 - Characteristics
7KHODEHOVDUH127WREHKLGGHQE\IRUHLJQREMHFWVDQGSDUWVUDJVER[HVHTXLSPHQWHWF
they must be regularly cleaned and always kept in sight.
I
dentification of the equipment and manufacturer
The technical data provided in this manual does not substitute the data
supplied on
WKHODEHOVDI¿[HGWRWKHHTXLSPHQW
7KHODEHOVDI¿[HGWRWKHHTXLSPHQWPXVW127EHUHPRYHGGDPDJHGVWDLQHGKLGGHQHWF
for any reason whatsoever.
The approval label contains the following information:
1. Manufacturer
2. Model
3. Rating data
&HUWL¿FDWLRQPDUNV
V
dc max
I
dc max
V
dc Operating Range
V
dc MPP
I
sc max
V
acr
f
r
I
ac max
P
acr (cos = ±0.9)
φ
V
acr
f
r
S
acr
I
ac max
MODEL:
REACT2-UNO-3.6-TL
575 V
90 - 575 V
2 x 12 A
160 - 480 V
2 x 15 A
Made in Italy
PROTECTIVE CLASS: I
230 V 1Ø
50 Hz
3200 W
3600 W
16 A
INVERTER
SOLAR
www.abb.com/solar
PROTECTIVE
EARTHING
REQUIRED
230 V 1Ø
50 Hz
3000 VA
13 A
Adj. cos
φ
P
acr (cos
= 1)
φ
P
ac max
IP65
5 minutes
-20 to + 55 °C
-4 to +131 °F
BACKUP OUTPUT
(1): Over/Under excited
0.1-1
(1)
BATTERY PORT
V
dc Operating Range
170 - 575 V
I
dc max (charge)
13.5 A
I
dc max (discharge)
10 A
S
max
3600 VA
3
2
4
1
V
dc max
I
dc max
V
dc Operating Range
V
dc MPP
I
sc max
V
acr
f
r
I
ac max
P
acr (cos = ±0.9)
φ
V
acr
f
r
S
acr
I
ac max
MODEL:
REACT2-UNO-5.0-TL
575 V
90 - 575 V
2 x 13.5 A
195 - 480 V
2 x 15 A
Made in Italy
PROTECTIVE CLASS: I
230 V 1Ø
50 Hz
4500 W
5000 W
22 A
INVERTER
SOLAR
www.abb.com/solar
PROTECTIVE
EARTHING
REQUIRED
230 V 1Ø
50 Hz
3000 VA
13 A
Adj. cos
φ
P
acr (cos
= 1)
φ
P
ac max
IP65
5 minutes
-20 to + 55 °C
-4 to +131 °F
BACKUP OUTPUT
(1): Over/Under excited
0.1-1
(1)
BATTERY PORT
V
dc Operating Range
170 - 575 V
I
dc max (charge)
13.5 A
I
dc max (discharge)
14 A
S
max
5000 VA
2
1
4
3
I
dc max (charge)
4.5 A
Contains Rechargeable Li-ion Battery
- Refer to instruction manual for proper installation.
- Do not remove the cover. No user serviceable parts inside.
- Do not expose the unit to heating sources.
- Do not expose the unit to direct solar irradiation.
- Do not install or operate the unit in potentially explosive
s.
atmosphere
WARNING!
www.abb.com/solar
BATTERY UNIT
REACT2-BATT
MODEL:
PROTECTIVE CLASS: I
Made in Italy
IP54
-20
55
(*)
to +
°C
-4
31
(*)
to +1
°F
V
dc max
575 V
W
hr
4.0 kWh
I
dc max (discharge)
5.6 A
V
dc operating range
170 - 575 V
(*): Out of 0 to +40 °C (+32 to +104 °F) temperature range, power derating occurs
4
1
2
3
Содержание REACT 2 Series
Страница 1: ...ABB solar inverters Product manual REACT 2 3 6 to 5 0 kW ...
Страница 159: ...Contact us www abb com solarinverters ...