- 109 -
000904AG
7 - Operation
Battery
- Battery Type. Select REACT2-BATT.
- Number. Set the number of REACT2-BATT (battery unit)
installed.
Energy Policy
- Energy Policy: set the way to manage the energy produ-
ced by the PV plant, choosing from the following:
Management
mode
Description
Zero injection
The system automatically manages
SRZHUÀRZVLQRUGHUWRDYRLGWKHLQMHF
-
tion of energy to the grid. If the meter is
disconnected or not working the inver-
ter’s output power is restricted to zero
in order to avoid accidental power fee-
ding to the grid.
Self consumption
The system automatically manages
SRZHUÀRZVLQRUGHUWRPD[LPLVHVHOI
consumption. All unused power from
domestic loads will feed into the grid.
Custom
The system automatically manages
SRZHUÀRZVLQRUGHUWRDYRLGIHHGLQJ
the grid with power greater than: PDC
x Plim
where PDC is the power of the pho-
tovoltaic generator (“PV GENERA-
TOR POWER” parameter) and Plim is
the output power limit with respect to
PDC(%) (“FEED-IN POWER” parame-
ter).
- PV Generator Power (Wp): Insert the
power value of the photovoltaic sy-
stem installed.
- Feed-in Power (% PV Generator Po-
wer): Set the percentage AC power
restriction (with reference to the value
of the photovoltaic system (kWp) in-
stalled) to be feed into the grid.
- Backup Mode:
Set the way to manage the backup funtionality, choosing from:
AUTO. The necessary condition for activating the backup
function is the lack of grid.
External Control. The backup function is controlled by an
external command.