PME120/RHD250 to 4000 (Contrac)
ELECTRICAL ROTARY ACTUATOR | OI/PME/RHD250/4000-EN REV. F
23
Figure 15: Link rod, all dimensions in mm (in)
PME120
RHD250
RHD500 / RHD800
RHD1250 / RHD2500
RHD4000
A
A
62 to 78(2.44 to 3.07)
100 to 120(3.94 to 4.72)
105 to 120(4.13 to 4.72)
100 to 140(4.33 to 5.51)
135 to 165(5.31 to 6.50)
B =L
−
(2xA)
=L
−
(2xA)
=L
−
(2xA)
=L
−
(2xA)
=L
−
(2xA)
C
60 (2.36)
99 (3.90)
99 (3.90)
120 (4.72)
163.5 (6.44)
D
46 (1.81)
84 (3.31)
79 (3.11)
100 (3.94)
125.5 (4.94)
E
Ø14 (Ø0.55)
Ø18 (Ø0.71)
Ø22 (Ø0.87)
Ø26 (Ø1.02)
Ø38 (Ø1.50)
F
15 (0.59)
18 (0.71)
28 (1.10)
24.5 (0.96)
30.5 (1.20)
G
14 (0.55)
18 (0.71)
21 (0.83)
25 (0.98)
37 (1.46)
H
18 (0.71)
23 (0.91)
23 (0.91)
32 (1.26)
42.5 (1.67)
I
61 (2.40)
74 (2.91)
91 (3.62)
104.5 (4.11)
141 (5.55)
B
A 8
−
0.015 /
−
0.051
(0.31 +0.0006 / +0.002)
8
−
0.015 /
−
0.051
(0.31 +0.0006 / +0.002)
14
−
0.018 /
−
0.061
(0.55 +0.0007 / +0.0024)
20
−
0.022 /
−
0.074
(0.79 +0.0009 / +0.0029)
25
−
0.018 /
−
0.061
(0.98 +0.0007 / +0.0024)
B
48 (1.89)
60 (2.36)
80 (3.15)
120 (4.72)
140 (5.51)
C
Ø24 +0.033 / 0
(Ø0.95 +0.0013 / 0)
Ø30 +0.033 / 0
(Ø1.18 +0.001 / 0)
Ø50 +0.039 /0
(Ø1.97 +0.0015 / 0)
Ø70 +0.076 / +0.030
(Ø2.76 +0.030 / +0.001)
Ø85 +0.090 / +0.036
(Ø3.35 +0.090 / +0.001)
D
32 (1.26)
40 (1.57)
63 (2.48)
75 (2.95)
87 (3.43)
E
27 +0.2 (1.06 +0.008)
33.3 +0.2 (1.31 +0.079)
53.8 +0.2 (2.12 +0.0078)
74.9 +0.2 (2.95 +0.008)
90.4 +0.2 (3.56 +0.008)
F
100 (3.94)
120 (4.72)
150 (5.91)
200 (7.87)
–
G
125 (4.92)
150 (5.91)
200 (7.87)
250 (9.84)
–
H
–
–
–
300 (11.81)
–
I
150 (5.91)
200 (7.97)
250 (9.84)
350 (13.78)
400 (15.75)
J
Ø25 (Ø0.98)
Ø40 (Ø1.57)
Ø48 (Ø1.89)
Ø60 (Ø2.36)
Ø76 (Ø2.99)
K Ø21,
Ø20*
(Ø0.83, Ø0.79*
)
Ø35.5, Ø32*
(Ø1.40, Ø1.26*)
Ø41, Ø37.5*
(Ø1.61, Ø1.48*)
Ø52.5, Ø48,5*
(Ø2.07, Ø1.91*)
Ø68, Ø58*
(Ø2.68, Ø2.28*)
C
A
201 (7.91)
265 (10.43)
343 (13.50)
460 (18.11)
537 (21.14)
B
32 (1.26)
50 (1.97)
70 (2.76)
100 (3.94)
140 (5.51)
C
9 (0.35)
21 (0.83)
26 (1.02)
35 (1.69)
43 (1.69)
D
19 (0.75)
21 (0.83)
25 (0.98)
30 (1.57)
40 (1.57)
* Level actuator US design