PME120/RHD250 to 4000 (Contrac)
ELECTRICAL ROTARY ACTUATOR | OI/PME/RHD250/4000-EN REV. F
41
RHD500 / RHD800
Mounting position
IMB 3
IMB 6
IMB 7
IMV 5
IMV 6 / IMB 8
Minimum oil level l (gal)*
Approx. 10 (2.65)
Approx. 11.5 (3.04)
Approx. 10 (2.65)
Approx. 10 (2.65)
Approx. 10 (2.65)
Minimum oil level under inspection
plug mm (in)
57 (2.24) Lower edge of upper oil
plug
15 (0.59)
37 (1.46) Lower edge of upper oil
plug
RHD1250 / RHD2500
Mounting position
IMB 3
IMB 6
IMB 7
IMB 8
IMV 5
IMV 6
Minimum oil level l (gal)*
Approx. 29 (7.67) Approx. 32 (8.47)
Approx. 24 (6.34)
Approx. 24 (6.34) Approx. 33 (8.72) Approx. 26.5 (7.01)
Minimum oil level under inspection
plug mm (in)
75 (2.95)
90 (3.54)
200 (7.87) Lower edge of upper oil plug.
Delivered filled with 33 l
(8.72 gal*).
34 (1.34)
35 (1.38)
RHD4000
Mounting position
IMB 3
IMB 6
IMB 7
IMB 8
IMV 5
IMV 6
Minimum oil level l (gal)*
Approx. 29 (7.67) Approx. 32 (8.47) Approx. 24.5 (6.47)
Approx. 24 (6.34) Approx. 34 (8.98) Approx. 26.5 (7.01)
Minimum oil level under inspection
plug mm (in)
75 (2.95)
90 (3.54)
200 (7.87) Lower edge of upper oil plug.
Delivered filled with 33 l
(8.72 gal*).
34 (1.34)
35 (1.38)
* US