24
PME120/RHD250 to 4000 (Contrac)
ELECTRICAL ROTARY ACTUATOR | OI/PME/RHD250/4000-EN REV. F
6
Electrical connections
Safety instructions
WARNING
Risk of injury due to live parts!
Risk of death or serious injuries due to electricity and
unexpected machine movements. In automatic mode the
motor is always under power, even at standstill.
• When working on the actuator or the related subassembly,
switch off the supply voltage for the electronic unit and
separate anti-condensation heater (option), and take
precautions to prevent unintentional switch-on.
The electrical connection may only be established by authorized
specialist personnel.
Notices on electrical connection in this instruction must be
observed; otherwise, electric safety and the IP-rating may be
adversely affected.
Safe isolation of electric circuits which are dangerous if touched
is only guaranteed when the connected devices fulfill the
requirements of EN 61140 (basic requirements for secure
separation).
To ensure safe isolation, install supply lines so that they are
separate from electrical circuits which are dangerous if touched,
or implement additional isolation measures for them.
Each actuator requires a suited Contrac electronic unit with
installed actuator-specific software. Observe the information in
the operating instruction. The specifications on the name plates
of the electronic unit and actuator must match to guarantee
correct hardware and software allocation.
Conductor cross-section on universal plug
PME
Actuators with separate electronic unit
Crimp pins
Motor / brake / heater
max. 1.5 mm
2
(16 AWG)
Signals
max. 0.5 mm
2
(20 AWG)
Contact surface
Motor / brake / signals:
Gold-plated
Heater: Silver-plated
Actuators with separate electronic unit
Screw terminals (optional)
Motor / brake / heater / signals 0.2 to 2.5 mm
2
(24 to 14 AWG)
Contact surface
Motor / brake / signals:
Gold-plated
Heater: Silver-plated
Actuators with integrated electronic unit
Crimp pins
Mains max.
1.5
mm
2
(16 AWG)
Signals
max. 0.5 mm
2
(20 AWG)
Contact surface
Gold-plated
Actuators with integrated electronic unit
Screw terminals (optional)
Power supply, signals
0.2 to 2.5 mm
2
(24 to 14 AWG)
Contact surface
Gold-plated
RHD
Crimp pins
Motor / brake / heater
max. 1.5 mm
2
(16 AWG)
Signals
max. 0.5 mm
2
(20 AWG)
Contact surface
Gold-plated
Screw terminals (optional)
Motor / brake / heater
max. 2.5 mm
2
(14 AWG)
Signals
max. 2.5 mm
2
(14 AWG)
Contact surface
Motor / brake / signals:
Gold-plated
Heater: Silver-plated