Tension Electronics PFEA113, User Manual
Section 4.7.1 Web Tension
3BSE029382R0101 Rev C
4-7
4.7.1.2 Segmented Roll
Segmented Roll Scale Factor (SRSF) is used to compensate the wrap gain to get a correct
measurement reading when not all rolls are supported by load cells in a segmented roll
application. For simplified calculations of SRSF, refer to
Appendix A.3.1 Segmented Roll Scale
.
•
Segmented roll (one input)
–
Tension A
•
Segmented roll (two inputs)
–
WebTension
(total web tension = A+B)
–
Tension A, Tension B, TensionDiff A-B
•
Segmented roll (three inputs)
–
WebTension
(total web tension = A+B+C)
–
Tension A, Tension B, Tension C, TensionDiff A-C
•
Segmented roll (four inputs)
–
WebTension
(total web tension = A+B+C+D)
–
Tension A, Tension B, Tension C, Tension D, TensionDiff A-D
4.7.1.3 Single Side Measurement (One Load Cell)
The following menus are shown when only one load cell per roll (single side measurement) is
connected to the tension electronics:
•
Web Tension
(One roll, load cell A or B)
•
TensionRoll 1
(Two rolls, Roll 1, load cell A or B)
•
TensionRoll 2
(Two rolls, Roll 2, load cell C or D)
Web Tension
,
TensionRoll 1 or TensionRoll 2
is the tension measured by a single load cell
multiplied by 2.