Tension Electronics PFEA113, User Manual
Section A.4 Technical Data
3BSE029382R0101 Rev C
A-9
Table A-8. Data for Digital Outputs
Data
Comments
Rated current (state 1)
0.1 A per output
Table A-9. Measurement Ranges for the Tension Electronics
Type
Range
(1)
(1) F
nom
= Load cell nominal load
Zero Setting Range
±2.0
F
nom
Dynamic Measurement Range
(including zero set)
–2.5
F
nom
to + 3.5
F
nom
Table A-10. Communication PFEA113
Data
Comments
Profibus
1
12 Mbit
Communication
protocol
Profibus DP slave
According to EN 50 170
Transfer speed
Max. 12 Mbits / s
Address range
0 - 125
RS-232
Not used