Tension Electronics PFEA113, User Manual
Section 3.10 Checking Load Cell Function
3BSE029382R0101 Rev C
3-11
3.10 Checking Load Cell Function
The “Hanging Weight” procedure can also be used as a function test on load cells,
see
The rope should then be placed in the web path but as close as possible to one of the load cells.
The output signal should be noted, and the rope moved close to the other load cell. Check that
the difference in output signal is small.
Figure 3-2. Load Cell Function Test