Tension Electronics PFEA113, User Manual
Appendix B PFCL 301E - Designing the Load Cell Installation
B-10
3BSE029382R0101 Rev C
Table B-1. Environmental data for load cell PFCL 301E
PFCL 301E
Unit
Compensated temperature range
+20 - +60
(68 - 140)
C
(
F)
Zero point drift
< ± 150
(83)
ppm/K
(ppm/
F)
Sensitivity drift
< ± 250
(139)
Working temperature range
-10 - +80
(14 - 176)
C
(
F)
Zero point drift
< ± 250
(139)
ppm/K
(ppm/
F)
Sensitivity drift
< ± 350
(194)
Storage temperature range
-40 - +90
(-40 - 194)
C
(
F)
Degree of protection
IP 66 acc. to EN 60 529
Table B-2. Mounting screws
Type of screws
Strength class
Dimension
Tightening
torque
Electro-zincplated steel screws,
lubricated with oil or emulsion.
Strength class according to ISO 898/1.
8.8
M8
24 Nm
(18 ft-lb)
Содержание PFEA 113