Tension Electronics PFEA113, User Manual
Appendix D PFRL 101 - Designing the Load Cell Installation
D-6
3BSE029382R0101 Rev C
D.6.2 Inclined Mounting
Sometimes it is necessary to mount the load cell on an
incline due to mechanical design constraints of the
machine or due to the need to have a proper force
component applied to the load cell.
Inclined mounting adds a component of tare force and
modifies the force components as shown.
NOTE
When calculating it is important that the
angles are set into the equations with the
correct signs relative to the horizontal
plane.
F
R
= T × [cos(
)
cos(
)]
F
Rtot
= F
R
+ F
RT
=
F
RT
=
Tare × sin
T × [cos(
)
cos(
)] + (
Tare × sin
)
F
R
Tare
Tare
F
V
F
V
F
R
T
T
T
T
Wrap gain
T
FR
--------
T
T
+
cos
–
cos
–
----------------------------------------------------------------------
=
=
T (Tension)
Wrap gain
FR
=
Wrap gain
1
+
cos
–
cos
–
-------------------------------------------------------------
=