Procedure
Use the following procedure to fit the connectors.
Note/illustration
Action
Cut the cable to desired length.
1
2
1
3
4
4
PE1
3
PE2
1
2
xx2100001258
Description
L1
1
L2
2
L3
3
Not used
4
Protective earth
PE1
Protective earth
PE2
Connect the wires according to the illus-
tration.
2
Tighten the screws to secure the cables.
3
Remove screw and washer on top of
contact and insert the ground cable with
cable lug. Secure with washer and
screws.
4
82
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.5.5 Fitting the connector for incoming mains
Continued