Value
Parameter
-3% ~ +10%
Voltage tolerance
4 A
Max output current
Note
The 24 V terminal block power supply is isolated from the internal logical circuit
of the controller.
For connection details, see
Circuit diagram - OmniCore V400XT
,
3HAC082020-008
.
Customer cable layout
It is recommended to use multicore cable for the customer connection.
The cables connected by customer to the 24 V terminal block should go through
the cable grommet and fasten on the cabinet.
Note
The diameter of the cables must match the diameter of the grommet.
Incorrect installation will affect the ingress protection.
It is recommended to use
icotek
KT grommet.
106
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A