Installation and Start-up Guide for NMBP-01
5-9
Data set 1 - CONTROL
The Control Word is used for fast drive control. This is a 16-bit word, where
each of the bits have its own, defined meaning. The bits are listed in Table 5-2
below.
Table 5-2 The Control Word.
Note: The normal stop mode is defined with Parameter 21.3.
Note: The Control Word is used for communication loss detection. The use of
the Control Word for communication loss detection is configured using the
Parameters 30.18 and 30.19.
Bit
Name
Description
0
reserved
1
RUN ENABLE
1 = Enabled
0 = Coast to stop
2
reserved
3
START/STOP
0 -> 1 Start the drive
0 = Stop the drive to normal stop mode
4
reserved
5
CNTRL_MODE
0 = Select Control Mode 1
1 = Select Control Mode 2
6
QUICK_STOP
1 = Stop the drive to quick stop mode
0 = Quick stop mode not selected
7
reserved
8
RESET FAULT
0->1 Reset drive fault
9 – 15
reserved