2TLC172315M0201 Rev.M3
36
Magne 4 DYN:
DYN output
15 mA (current limited)
Response time at activation
<100 ms
Response time at
deactivation
<30 ms
Magne 4 OSSD:
OSSD output
Max. 50 mA per output (current limited)
Response time at activation
<100 ms
Response time at
deactivation
First unit <30 ms
For each additional unit < 10 ms
Voltage drop for OSSD
output
VCC - 2.5 VDC at 25 mA
Power from switched off
position (OSSD out)
<3
µ
A
Safety / Harmonized standards
Conformity
European Machinery Directive 2006/42/EC
EMC directive 2014/30/EU
RoHS directive 2011/65/EU
RoHS3 directive 2015/863
Application standard
compliance
EN ISO 14119:2013
Functional safety standard
compliance
EN ISO 12100:2010
EN ISO 13849-1:2015, PL e/Category 4, PFH
D
= 4.50·10
-9
EN ISO 13849-2:2012
EN 62061:2005+A1:2012+A2:2015, SIL3, PFH
D
= 4.50·10
-9
EN 61508:2010,
SIL3, PFH
D
= 4.50·10
-9
Warning!
The safety related values are based on interlocking
device Eden and are not valid for the locking function.
Electrical safety standard
compliance
EN 60204-1:2006+A1:2009
EN 60664-1:2007
Electromagnetic
compatibility standard
compliance
EN 60947-5-2:2007+A1:2012
EN 60947-5-3:2013
Certificates
cULus, TÜV Süd
Information for use in USA/Canada (UL)
Enclosure
Type 1
Intended usage
Applications according to NFPA 79
Connecting cables
Cables to comply with CYJV/7, with a conductor area of
min. 0.2 mm
2
.