2TLC172315M0201 Rev.M3
26
7
Functions
7.1
Locking function
Power is needed to lock Magne. A loss of power will result in unlocking.
Locking:
•
Close the door.
•
Lock by ap24 VDC on the locking pin.
Unlocking:
•
Unlock by re24 VDC from the locking pin.
•
Open the door.
7.2
Interlocking function
An interlocking function monitors the door position, open or closed, but it does not prevent
the door from being opened.
7.3
LED Indications
Status LED indications show the status of Magne and its outputs.
Magne 3 and Magne 4 have one blue LED (locked/unlocked indicator).
Magne 4 also has one green and one red LED (Eva position indicator).
Model
LED Indication
Description
Safety
circuit
Magne 3 +
Magne 4
Blue
Magne is locked
N/A
Magne 3 +
Magne 4
Blue flashing
Lock signal, but Magne is not detecting the
anchor plate
N/A
Magne 4
Green
Eva within sensing distance of Adam (door
closed)
Closed
Magne 4
Green flashing
Eva within 2 mm from maximum sensing
distance
(door closed)
Closed
Magne 4
Green-Red
flashing
Eva within sensing distance, safety circuit
before this unit broken (door closed)
Open
Magne 4
Red
Eva out of sensing distance (door open)
Open
Magne 4
Red flashing
Eva code not stored in Adam
Open
Magne 4
Red fast
flashing
Fail safe mode
Open
Magne 4
(OSSD)
Red-Red-Green
fast flashing
Invalid
input signal
Open
See recommended actions to take in chapter ‘Troubleshooting’.