2TLC172315M0201 Rev.M3
16
5
Connections
Connection diagrams with pin outs for different Magne models.
Warning!
Always use shielded cables to connect the unit to the rest of the safety circuit.
5.1
Safety signal
DYNlink signal – one channel
Magne DYN models use the ABB DYNlink signal as safety signal and must be used with ABB
Vital safety controller and/or ABB Pluto safety PLC.
All products using the DYNlink signal can be mixed and connected in series. Up to 30 DYNlink
devices with a Vital and up to 10 DYNlink devices per Pluto input can be connected while
maintaining PL e (EN ISO 13849-1:2015).
OSSD signal – two channels
Magne OSSD (Output Signal Switching Devices) models can be used with any safety control
module that can handle OSSD signals. Up to 30 Magne OSSD can be connected in series while
maintaining PL e (EN ISO 13849-1:2015).
200
µ
s
95 ms
190 ms