Axle Holding force at door handle
Y
Holding force (kN)
X
Offset between Magne unit and door handle (m)
4.3.4
Installation Anchor plate
Anchor plate (B) is installed with cellular rubber (C) between the anchor plate and the bracket
(G) mounted on the door. The cellular rubber is attached to the anchor plate with adhesive
tape and enables the anchor plate to adjust to Magne.
Use suitable M8 screw (F). Leave enough room for the cellular rubber to ensure movement of
the anchor plate.
Recommended tightening torque is 7 Nm ±2.
Note!
Do not compress the cellular rubber to a thickness less than 8 mm.
Do not overtighten the screw. This can deform the anchor plate, causing reduced
or no holding force. A deformed anchor plate must be replaced.