Installing the LWT
17
Assembling a segmented probe
Segmented probes are rod probes divided in 1-meter (3.3 feet) segments that must be assembled on
site. Each segment is inserted into the vessel at the moment of assembly, starting with the end-of-
probe segment. The following explains the assembly procedure.
To assemble a segmented probe on site:
1
Slide in the head lock on the set-screw fixed on one of the probe segments.
2
Screw the female end of the end-of-probe segment on the male end of the first segment and tighten
by hand.
—
Figure 5
Assembling two segments of a segmented probe
Lock
3
Use two wrenches (each one holding the probe slot of the segment) to apply the recommended
torque (see below) in opposite directions at the same time (see Figure 5 on page 17).
NOTICE
There are two sizes of head locks: 8.9 mm (0.35 in) and 13.5 mm (0.53 in). The
recommended torque, as specified by the manufacturer, is as follows:
• For the 8.9 mm lock: 2.8 N·m (2.1 lbf.ft).
• For the 13.5 mm lock: 13.5 N·m (10.0 lbf.ft).
Содержание LWT300 series
Страница 1: ... USER GUIDE LWT300 series Guided wave radar level transmitter Modbus ...
Страница 36: ...Page intentionally left blank ...
Страница 40: ...Page intentionally left blank ...
Страница 66: ...Page intentionally left blank ...
Страница 70: ...Page intentionally left blank ...
Страница 76: ...Page intentionally left blank ...
Страница 96: ...Page intentionally left blank ...
Страница 98: ...Page intentionally left blank ...
Страница 104: ...Page intentionally left blank ...
Страница 105: ...Page intentionally left blank ...
Страница 106: ...Page intentionally left blank ...
Страница 107: ......