Removing the balancing device
Use these procedures to remove the balancing device.
Preparations before removing the balancing device
Note
Action
xx2200001458
Jog axis-2 to the calibration position.
1
Lock screw, M16x120
Fit a lock screw through the hole for the
lock screw in the frame and into the lower
arm to secure the weight of the lower and
upper arms.
CAUTION
Do not tighten the lock screw, since too
hard tightening could damage the gear.
2
xx2200001332
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the safe-
guarded space.
3
Remove any installed equipment on or
close to the balancing device.
4
Continues on next page
Product manual - IRB 6730
213
3HAC085699-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the balancing device
Continued