4 Repair
4.5.1. Replacement of SMB unit
311
3HAC023082-001 Revision: E
©
Co
py
rig
h
t 200
4-
200
8 ABB. All righ
ts reser
v
ed.
Refitting, SMB unit
The procedure below details how to refit the SMB unit.
Action
Note
1.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
For Foundry Prime robots: Do not turn off the air
pressure to motors and SMB.
2.
esd
WARNING!
The unit is sensitive to ESD, before handling the
unit please observe the safety information in
section
WARNING - The unit is sensitive to ESD!
3. Connect the
battery cable
to the SMB unit.
.
4. Connect all connectors to the SMB board and fit
the
SMB unit
onto the
pins
.
Art. no. is specified in
!
!
R1.SMB1-3, R1.SMB4-6 and R2.SMB
5. Secure the SMB unit to the pins with the nuts and
washers.
6. If disconnected, reconnect the connectors X8, X9
and X10 to the brake release board.
7. Secure the
SMB cover
with its attachment
screws.
!
8. Update the revolution counter!
Detailed in chapter Calibration -
section
9.
DANGER!
Make sure all safety requirements are met when
performing the first test run. These are further
detailed in section
cause injury or damage! on page 38
.
Continued
Continues on next page
Содержание IRB 6600 - 225/2.55 type B
Страница 2: ......
Страница 10: ...Table of Contents 8 3HAC023082 001 Revision E Copyright 2004 2008 ABB All rights reserved ...
Страница 18: ...How to read the product manual 3HAC023082 001 Revision E 16 Copyright 2004 2008 ABB All rights reserved ...
Страница 512: ... Copyright 2004 2006 ABB All rights reserved Revision 02 sheet Circuit Diagram 3HAC 13347 1 Contents 101 ...
Страница 514: ... Copyright 2004 2006 ABB All rights reserved Revision 02 sheet Circuit Diagram 3HAC 13347 1 Legend 103 ...
Страница 515: ... Copyright 2004 2006 ABB All rights reserved Revision 02 sheet Circuit Diagram 3HAC 13347 1 Brake Release Unit 104 ...
Страница 517: ... Copyright 2004 2006 ABB All rights reserved Revision 02 sheet Circuit Diagram 3HAC 13347 1 Axis 1 106 ...
Страница 518: ... Copyright 2004 2006 ABB All rights reserved Revision 02 sheet Circuit Diagram 3HAC 13347 1 Axis 2 107 ...
Страница 519: ... Copyright 2004 2006 ABB All rights reserved Revision 02 sheet Circuit Diagram 3HAC 13347 1 Axis 3 108 ...
Страница 520: ... Copyright 2004 2006 ABB All rights reserved Revision 02 sheet Circuit Diagram 3HAC 13347 1 Axis 4 109 ...
Страница 521: ... Copyright 2004 2006 ABB All rights reserved Revision 02 sheet Circuit Diagram 3HAC 13347 1 Axis 5 IRB 7600 110 ...
Страница 522: ... Copyright 2004 2006 ABB All rights reserved Revision 02 sheet Circuit Diagram 3HAC 13347 1 Axis 6 111 ...
Страница 523: ... Copyright 2004 2006 ABB All rights reserved Revision 02 sheet Circuit Diagram 3HAC 13347 1 Switches axis 1 113 ...
Страница 524: ... Copyright 2004 2006 ABB All rights reserved Revision 02 sheet Circuit Diagram 3HAC 13347 1 Switches Fan axis 2 114 ...
Страница 525: ... Copyright 2004 2006 ABB All rights reserved Revision 02 sheet Circuit Diagram 3HAC 13347 1 Switches Fan axis 3 115 ...
Страница 526: ... Copyright 2004 2006 ABB All rights reserved Revision 02 sheet Circuit Diagram 3HAC 13347 1 Axis 5 IRB 6600 901 ...
Страница 527: ... Copyright 2004 2006 ABB All rights reserved Revision 02 sheet Circuit Diagram 3HAC 13347 1 Design changes note 1 1 905 ...
Страница 532: ......