Removal of mechanical stop, axis 4
The procedure below details how to remove the mechanical stop of axis 4, to enable
the function
Resetting the work area for an axis
.
WARNING
When the damper is removed from axis 4, the axis does not have a mechanical
stop! If the robot is provided with cabling on the upper arm, the cabling can be
damaged when the function
Resetting the work area for an axis
is used, or if the
robot is jogged uncalibrated.
Info/Illustration
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply (do not turn off for
Foundry Prime robots!)
to the robot, before entering the robot work-
ing area.
1
Shown in the figure
Loosen the
attachment screws, mech stop
and remove the
mechanical stop, axis 4
.
2
Slowly rotate axis 4 until the damper is visible
through the hole.
3
Remove the damper.
4
4 pcs, M8x16. Tightening torque: 24 Nm.
Refit the mechanical stop to the axis 4 with
its attachment screws.
5
82
Product manual - IRB 4400
3HAC022032-001 Revision: Q
© Copyright 2004-2018 ABB. All rights reserved.
2 Installation and commissioning
2.5.5 Unlimited working range
Continued
Содержание IRB 4400 - L10
Страница 1: ...ROBOTICS Product manual IRB 4400 ...
Страница 2: ...Trace back information Workspace R18 1 version a9 Checked in 2018 03 22 Skribenta version 5 2 025 ...
Страница 8: ...This page is intentionally left blank ...
Страница 94: ...This page is intentionally left blank ...
Страница 282: ...This page is intentionally left blank ...
Страница 294: ...This page is intentionally left blank ...
Страница 296: ...This page is intentionally left blank ...
Страница 302: ......
Страница 303: ......