Note
Action
Select the desired unit and choose
Rev Counter Update
from the
Calib
menu.
The
Revolution Counter Update
window appears.
xx0100000202
3
Select the desired axis and press
Incl
to include it (it will be marked
with an x) or press
All
to select all axes.
4
Press
OK
when all axes that are to be updated are marked with an x.
CANCEL
returns to the
Calibration
window.
5
Press
OK
again to confirm and start the update.
CANCEL
returns to the
Revolution Counter Update
window.
6
Not required.
At this point, it is
recommended
that the revolution counter values are
saved to a diskette.
7
CAUTION
If a revolution counter is incorrectly updated, it will cause incorrect
manipulator positioning, which in turn may cause damage or injury!
Check the synchronization position very carefully after each update.
8
How to perform the check is detailed in section
Continues on next page
Product manual - IRB 4400
271
3HAC022032-001 Revision: Q
© Copyright 2004-2018 ABB. All rights reserved.
5 Calibration
5.5 Updating revolution counters
Continued
Содержание IRB 4400 - L10
Страница 1: ...ROBOTICS Product manual IRB 4400 ...
Страница 2: ...Trace back information Workspace R18 1 version a9 Checked in 2018 03 22 Skribenta version 5 2 025 ...
Страница 8: ...This page is intentionally left blank ...
Страница 94: ...This page is intentionally left blank ...
Страница 282: ...This page is intentionally left blank ...
Страница 294: ...This page is intentionally left blank ...
Страница 296: ...This page is intentionally left blank ...
Страница 302: ......
Страница 303: ......